Pub. 988-0154-641
EP-90R Pressure
Electronic Sensor
Installation and Configuration Instructions
This document shows how to install an EP-90R Pressure sensor and
how to connect it to a NMEA 2000
®
network. It also provides
instructions on how to configure your pressure sensor with Lowrance
digital gauges (LMF-200 & LMF-400) and display units.
NMEA 2000 is the communication bus standard developed by the
National Marine Electronics Association (NMEA) for use in boats.
Lowrance has introduced a line of products that can communicate over
a NMEA 2000 network (LowranceNet).
All Lowrance NMEA 2000 capable devices are either NMEA 2000
certified or certification is pending.
CAUTION:
Installing LowranceNET NMEA 2000 devices is significantly
different from installing earlier Lowrance components without
NMEA 2000 features. You should read all of the installation
instructions before proceeding. Decide where you want to install
all components before drilling any holes in your vessel.
Some sonar or GPS display units may require a software upgrade to
display NMEA 2000 data correctly. For free software upgrades or
additional information on the LowranceNet NMEA 2000
®
network
system, visit our web site, www.lowrance.com.
EP-90R Pressure Sensor.
Hose barb
attachment
Red NMEA 2000
connector
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - EP-90R Pressure

1 Pub. 988-0154-641 EP-90R Pressure Electronic Sensor Installation and Configuration Instructions This document shows how to install an EP-90R Press

Page 2

104. Use the UP and DOWN keys to input the number of gallons the tank will hold and press MENU. Repeat steps 3 and 4 for each additional tank. After

Page 3 - Installation

11To unconfigure the EP-90R: 1. Press MENU, select SYSTEM SETUP and press MENU. 2. Highlight BUS DEVICES and press MENU. Select a configured pressu

Page 4

12Adding a page: 1. Press MENU, use the UP and DOWN keys to select PAGES and press MENU, which will open the Pages menu with the following options: A

Page 5

13up to three options. (If your unit is configured for one engine, or if you chose Pitot Speed or Atmospheric Pressure, you will be directed back to

Page 6

143. Select the desired option and press MENU. The Pressure Range menu will appear with the following options: 0-30 psi, 0-60 psi, 0-80 psi and 0-100

Page 7

15LMF-400: EP-90R Pressure Configuration This section covers how to use your EP-90R Pressure Sensor with the LMF-400 Multi-function gauge. LMF-400

Page 8

165. After all tanks on your vessel have been set up, press EXIT repeatedly to return to the main display. Boat Setup Reset If you want to access th

Page 9 - Pressure Configuration

174. Press ENTER. You will be taken back to the Bus Devices list. Press EXIT repeatedly to return to the main display. To reconfigure the EP-90R: 1.

Page 10

18Customizing Pages The customizing pages feature allows you to choose what data will be displayed on selected pages. You can use the Single Analog,

Page 11

19To customize Quad Analog page: 1. Make sure the Quad Analog page has been added to the page screen rotation. 2. Use the ENTER and EXIT keys to scr

Page 12

2 The EP-90R consists of a red cable connector and the EP-90R housing with standard size hose barb attachment. The EP-90R Water Pressure sensor, lik

Page 13

205. Highlight PITOT SPEED, ENG BST PRESS, ENG OIL PRESS, ENG WTR PRESS, FUEL PRESSURE, TRNS OIL PRESS or ATM PRESSURE and press ENTER. The Sel

Page 14 - Warning Threshold

21Pressure Range (Analog Pages only) From the Single, Dual and Quad Analog pages, you can set pressure ranges for Boost, Oil, Fuel and Transmission O

Page 15 - Pressure Configuration

22To reset pressure sensor values: 1. Press MENU, select SYSTEM SETUP and press ENTER. 2. Highlight BUS DEVICES and press ENTER. 3. Select the desire

Page 16

23Display Unit: EP-90R Pressure Configuration This section will show you how to use an EP-90R Pressure Sensor with a display unit. The LMS-525cDF i

Page 17

24Engine & Tank Configuration The Engine-Tank configuration menu is located below the NMEA 2000 Devices list, but will only be accessible if engi

Page 18

259. When all tanks have been configured, highlight the SET CONFIGURATION button and press ENTER. The following confirmation message will appear: Are

Page 19

264. Use the UP and DOWN keys to change the Device Name. When you have finished inputting the desired Device Name, press ENTER. Press EXIT repeatedl

Page 20

27 To select Pressure Type: 1. Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER. A menu will appear with five options: Bus Setup, Fue

Page 21 - Reset Values

286. Highlight YES and press ENTER. Press EXIT repeatedly to return to the main display. NMEA 2000 Alarms When you set a NMEA 2000 Alarm for a pressu

Page 23 - Display Unit: EP-90R

3 For complete instructions on setting up a new NMEA 2000 network or expanding an existing one, see the other document packed with your EP-90R, "

Page 25 - Device Name

31LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRANCE ELECTRONICS, INC., the manufactur

Page 26

32How to Obtain Service… …in the USA: Contact the Factory Customer Service Department. Call toll-free: For Lowrance: 800-324-1356. For Eagle: 800-324

Page 27

4 3. Slide the pressure hose onto the EP-90R hose barb attachment. If it does not fit snugly, secure it with a zip tie at the base of the hose barb

Page 28 - NMEA 2000 Alarms

5 In similar fashion, a NMEA 2000 network allows multiple display units to receive data from a GPS antenna or multiple sonar units to receive message

Page 29

6 NMEA 2000 network node located at the end of a NMEA 2000 backbone. NOTE: If you have a double T Connector on your network that is not attached t

Page 30

7 In this example, a new device is added to the NMEA 2000 bus by installing a T connector between a T connector and a terminator at the end of the

Page 32 - How to Obtain Service…

9 LMF-200: EP-90R Pressure Configuration This section covers how to use EP-90R Pressure Sensor with the LMF-200 Multi-function gauge. NOTE: You will